OS-6 concentration controller 0-20ppm View larger

OS-6 concentration controller 0-20ppm

OS-6 0-20ppm

New product

OS-6 ozone concentration meter / controller 0-20ppm
 
Goods available on request.
Waiting time around 21 days

More details

  • OS-6 ozone concentration controller measuring range 0-20ppm accuracy 10-15%
    • Industrial monitor and controller adapted to work in difficult conditions
    • Reinforced, waterproof housing
    • Large, backlit digital screen
    • Automatic measurement in the range of 0-20ppm
    • Easy access to relays and mounting points
    • Pre-calibrated sensor module easy to replace
    • Relays controlled by setting points to control the generator
      and warnings
    • Power cut-off switch on the front panel for easy maintenance
    • The remote sensor module can be 30 m (100 with additional power) from the console
    • OSHA 0.1ppm warning LED
    • Digital and analog readings
     
    OS-6 is an industrial ozone level controller and monitor. Its implementation ensures accuracy, ease of installation, configuration and operation. All connectors and manipulators are located on the front panel to allow installation before configuring the device. The controller housing has been strengthened to provide protection against splashing and harsh industrial conditions. The setpoints for the ozone level control relays are digitally controlled and set using numerical values. This solution ensures easy configuration of the device even when no ozone is found in the environment. The front panel indicator lights display many important parameters, including the warning that the OSHA limit is exceeded by 0.1 ppm. The generator control switch allows you to turn off the generator from the panel. The user has the option of selecting ranges for the analog outputs (4-20 mA and 0-2 VDC). OS-6 is equipped with a fault detection module and the option for the user to set the time after which the device will go into emergency mode and report a fault.
    External outputs
    Illustration of a board with OS-6 controller connectors
    OS-6
    Connector description:
    • TB1: 12-24 VDC POWER: OS-6 power supply and grounding
    • TB2: ANALOG OUTPUT: 4-20mA and 0-2 VDC for external control.
    To learn more go to "Selecting the Analogue Range." The default range is 0-20 PPM.
    TIP: The 4-20 mA output serves as a DRIVER rather than as a permanent current source.
    • TB3: RS-232 OUT: Serial data output. For details, read "Data Connections".
    • TB4: GENERATOR CONTROL: Relay that supports user adjustable ozone levels. To learn more, go to "Ozone Control Relay Setpoints and Alarms".
    • TB5: ABOVE 0.1 PPM: Relay associated with OSHA security limit (for remote alarms / sirens).
    • TB6: UNABLE TO CONTROL OZONE: Relay associated with entering the emergency mode Unable to Control Ozone - Ozone level control impossible (for remote alarms / sirens).
    • TB7: GENERATOR ENABLE: A jumper is factory fitted to enable generator control using Generator Control (TB4). If the jumper has been removed and these terminals are not connected, the ozone controller connected to TB4 will not start. Remove the jumper or replace it with a switch to turn off the ozone generator during maintenance. The work should also be removed if the User wants to switch OS-6 to the ozone level monitoring mode. In this situation, if the jumper has been removed, the controller control relay (TB4) will be inactive, as will the "Generator Control" and "Unable to Control Ozone" indicator.
    • TB8: Sensor Data and Ground: Connect the cable from SM-4 TB1 BLK (ground) and WHT (data) to TB8.
    • TB9: SENSOR POWER: Power supply for the sensor. Connect the red wire to: + 5V out to SM-4 TB1 + 5V OR + 12-
    Technical data:
    • Measurement range: 0-20ppm
    • Display: LCD, numeric, four digits, 0.5 "/ 12mm, automatic range, backlight.
    • LED indicators: ozone detector, above MAX, below MIN,> 100 PPM, generator on, fault
    • Resolution: 0.01ppm
    • Sensitivity: 0.01ppm ± 20%
    • Accuracy: 20%
    • Power supply: 12-24 VDC / 300-500mA (via external power supply)
    • Output power: +5 or + 12-24 VDC to the sensor.
    • Data input: RS-232 serial port from the remote sensor module (SM-4 or equivalent)
    • Data readout: RS-232 serial port, 9600 Baud 8N1 format.
    • Analogue reading: 0-2 V and 4-20 mA, full scale range set using internal sphincters.
    • Input control: generator switch / power cut-off.
    • Output control: Relays, 10A @ 25VDC, 0.25A @ 250VDC, 2.0 KVA AC (resistor).
    • Relay functions: Ozone generator control, safety limit> 0.1 ppm, control error.
    • User control (internal): MAX point, MIN point, FAIL time (fault detection)
      after a set time), increase, decrease
    • Finish: Polycarbonate enclosure with wall mounting
    • Housing protection: splashproof (NEMA 4X).
    • Total size: Height = 6.3 "/ 160mm, width = 6.5 "/ 166mm, Depth = 4.6" / 118mm.
    • Size without sensor (SM-4):
    • Electric gear: 12v power supply