Sale Miernik ozonu w wodzie View larger

Ozone meter in water

New product

CHLORTROL + MICRO2CHEM MEASUREMENT OF CONTENT ABOUT 3 WATER

Two O3 measurement channels

DESTINY

The CHLORTROL measuring set is intended for continuous measurement of ozone content in pure water.

Main areas of application: drinking water installations in water treatment plants (SUW) and water intakes, technological installations requiring monitoring and control in order to preserve water parameters

(e.g. cooling installations, washing and rinsing installations, swimming pools).

More details

  • DISTINCTIVE FEATURES

    • Low cost while maintaining high technical parameters.
    • The electronic transmitter has a modular structure and is available in one or two channel version

    the basic version can be expanded at any time by adding additional modules, easily and at a low cost.

    • Easy change of the type of quantity measured from the configuration level, without having to replace the measuring set modules - this operation can be performed on site.
    • The unique "Vortex Cleaning" measuring electrode cleaning system that ensures stable measurement results and increases reliability; engine-susceptible solutions fail to do so.
    • Internal stabilization of sample pressure in the measuring chamber; the ability to work at pressures up to 16bar.
    • Low operating cost:

    in most applications, the measurements do not require the use of reagents, the spare parts supply is minimal, a small water sample is taken to measure, approx. 1 l / min.

    • Easy installation, commissioning and service, minimized service.

    SELECTED CHLORTROL + MICRO2CHEM TECHNICAL PARAMETERS

    sensor

    flow fittings:

    CHLORTROL

    with the unique "Vortex Cleaning" electrode cleaning system

    Measuring range (span):

    ozone

    min. 0 - 0.25 mg / l, max. 0 - 10.0 mg / l

    pH (0 ... 14)

    Measurement accuracy:

    ± 5% of the range

    Temperature of measured sample:

    2 oC - 50 oC

    Automatic compensation of the influence of sample temperature changes on the measurement result, integrated Pt100 temperature sensor

    Sample pressure:

    0.2 - 4 bar without any additional reduction

    4-16bar with pressure reducing valve, option recommended

    Sample Flow:

    approx. 30 l / h - 60 l / h

    Electronic transducer

    Micro2Chem, for wall mounting

    display:

    16-position display (measured value, temperature)

    Analogue output:

    4-20 mA or 0-20 mA, programmable

    Relay outputs:

    2 pcs.

    Digital communication:

    RS232 or RS485 (options - extra charge)

    Power supply:

    230 V / 50 Hz

    Signal cable:

    standard 1 m (or max. 10 m - option at extra charge)

    The cable connects the measuring chamber with the electronic converter.

    Parameter

    Measurement range

    O3 (ozone)

    0.00 - 10.00 ppm

    The Micro2Chem transmitter accepts signals

    measurements from the CHLORTROL sensor and / or signals from other external sensors (e.g. pH, oxygen or any sensor with 4 - 20 mA output).

    The measuring ranges are programmable for each channel separately.

    • For each measuring channel

    a separate output is assigned

    analog (0-20 mA or 4-20 mA); the outputs are galvanically isolated, with protection

    przeciwzwarciowym. Max. up to seven relay outputs - for use in automatic control systems and for signaling alarm states.

    • Power supply: 230 V / 50 Hz, power consumption: 20VA.
    • Wall mounting enclosures:

    - CHLORTROL / IP 66 sensor dimensions: 263 x 167 x 135 mm, weight approx. 2.5 kg

    - Micro2Chem electronic transducer: IP 65, 250 x 220 x 120 mm, weight approx. 3 kg.

    • The supply of spare parts has been kept to a minimum;